Ice and rain loads apply downward vertical forces to all above-ground pipe elements and fittings. Set ice shape factor to zero to exclude specific elements from ice load calculations.

Supported ice load standards:
ASCE 7-22 (USA)

Dk – Insulation outer diameter (defined in pipe properties)
c - Ice shape factor (defined in pipe properties)
- Ice
load unit weight (0.9 tf/m³)
fz - Height factor

IBC 2021 (International)
Same as ASCE 7-22
GB 50135-2019 (China)

Dk – Insulation outer diameter (defined in pipe properties)
c - Ice shape factor (defined in pipe properties)
- Ice
load unit weight (0.9 tf/m³)
SP 20.13330.2016 (Russia)

Dk – Insulation outer diameter (defined in pipe properties)
c - Ice shape factor (defined in pipe properties)
- Ice
load unit weight (0.9 tf/m³)
Property |
Description |
Insulation Outer Diameter |
Determines ice layer cross-sectional area for load calculation |
Elevation of Start/End Node |
Highest elevation value used for ice load calculation. Default elevation above ground surface calculates automatically assuming horizontal ground plane. Disable "Recalculation of elevation above ground surface" for pipelines on variable terrain. |
Ice Region |
Select ice region number from SP 20.13330.2016 maps |
Load Type |
SUS - sustained ice load, OCC - occasional ice load |
Basic Ice Thickness |
|
Wind Exposure |
|
Hill Shape |
|
Height of Hill, H |
|
Crest Distance, Lh |
|
Distance from Crest to Site, x |
|
Dialog opens automatically during new file creation or existing file opening. Access manually via File > Project Settings