Look up warning messages by code number.
Code |
Warning |
Cause and Solution |
|---|---|---|
W697 W539 |
W697 - Iteration convergence failed (R>0) W539 - Iteration convergence failed (D>0 and R<0) |
Simultaneous friction and single-directional restraint iterations did not converge. Follow E828 error recommendations W697 - Reaction in restricted direction (R>0). Example: upward reaction at resting support W539 - Displacement in allowed direction with reaction in same direction (D>0 and R<0) D = displacement in allowed direction, R = reaction in allowed direction |
W541 W693 W694 W696 W542 |
W541 - Solution integrity check failed (D<0) W104 - Solution integrity check failed (D!=0) W693 - Solution integrity check failed (|D/k-Z-R| < 0) W694 - Solution integrity check failed (D>DD) W696 - Displacement and friction force vectors not parallel W542 - Solution not obtained (problem x) |
Deformation check failed. Solution accuracy lost. Add more markers or adjust marker spacing. Follow E828 error recommendations W541 - Displacement in restricted direction of single-directional restraint (D<0) W104 - Non-zero displacement in double-acting restraint (D!=0) W693 - Spring deformation check failed (|D/k-Z-R| < 0) W694 - Displacement exceeds gap value (D>DD) W696 - Displacement and friction force vectors not parallel W542 - Send project file to technical support D = displacement, R = reaction, k = flexibility, Z = precompression, DD = gap |
W815 |
Solution integrity check failed (Fric!=Kfric*R) |
Friction force does not equal friction coefficient times reaction force. Send model file to developers |
W416 |
Insert reducer at diameter change node |
Add reducer element between pipes with different diameters |
W582 W583 |
Force/moment limit exceeded |
Support load exceeds maximum value defined in support properties |
W632 |
Allowable restraint subsidence applied |
Small support subsidence applied to improve single-directional restraint convergence. Informational message - no action required |
W305 |
Pipe lifted off support |
Single-directional restraint disabled - not carrying load. Warning only - no code violation. Pipe moves upward off support. Remove support if lifting occurs in all operating modes. If lifting occurs only in hot state, pipe returns to support when cold. Consider potential vibration and displacement issues. Engineer discretion required based on experience or company standards.
|
W670 |
Hanger rod rotation exceeds limit |
Limit defined in Project Settings. Default: 5° (Russian codes), 3° rigid/4° spring (Chinese D-ZD2010). Increase rod length to resolve |