Analysis of Maximum Length, Virtual Anchor Length, Elongation and Anchor Loads for Buried Pipeline

Read about START-PROF pipe stress analysis software

Related Topics

This analysis provides approximate calculations for:

The analysis also calculates anchor loads for specified section lengths.

Input data can be copied using the toolbar icon and transferred to other START-Elements analyses using the toolbar icon.

Input Data

 

 

Property

Description

External diameter, D

External pipe diameter

Pipe wall thickness, S

Nominal wall thickness

External casing diameter, Dc

External insulation casing diameter. Set to 0 for uninsulated pipes.

Casing thickness, SC

Insulation casing thickness

Depth, Z

Depth from soil surface to pipe centerline

Ambient temperature

Average wall temperature during pipe assembly. More...

Operation temperature

Operating temperature in operating state. More...

Uniform pipe weight

Uniform weight of piping and attached equipment. More...

Uniform insulation weight

Uniform insulation weight. More...

Uniform product weight

Uniform product weight. More...

Operation pressure, P

Operating pressure in operating state. Required for all standards except SNIP 2.05.06-85. More...

Insulation type

Armopenobeton, polymer, polyurethane, or other. For polyurethane, casing diameter DC and thickness SC auto-populate from database. For other types, enter manually.

Backfill soil number

Trench soil type from soil database

Base soil number

Native (undisturbed) soil type from soil database

Steel grade

Pipe material from materials database

Output

Analysis results include:

Property

Description

Maximum extension of compensation zone

Pipe end displacement after thermal expansion

Friction

Uniform soil-pipe friction force

Anchor Load

Maximum allowable longitudinal anchor force

Pipeline maximum length

Maximum straight section length without expansion joints

Pipeline virtual anchor length, La

Distance from pipe end to zero displacement point (sliding zone length). See also

Maximum stress

Maximum equivalent pipe stress

Allowable stress

Allowable stress per GOST R 55596-2013 and RD 10-400-01 (1.5[σ]), or design resistance per SNIP 2.05.06-85

- for buried pipelines

Menu Access

Pipe. Buried > Pipe Elongation