Ovalization Factor

Related Topics

Per RD 10-249-98 sections 5.1 and 5.2, the maximum initial ovalization factor for elliptical cross-sections is defined as:

When actual measured ovality data from bent pipes is unavailable (such as during design phase), perform two separate analyses:

Apply the ovalization factor in these analyses:

Note: According to RD 10-249-98 section 5.2.6.8, multiply the initial ovality factor a by 1.8 for low-temperature piping systems. PASS/START-PROF automatically applies this multiplier when using RD 10-249-98 section 5.2 criteria.

When initial ovality measures less than 3% per section 5.2.6.8, omit ovality considerations from stress analysis. PASS/START-PROF does not automatically apply this exclusion.