PASS/NOZZLE-FEM 3.5. Program Manual |
Fig. 4.5. Coordinates system associated with main shell orientation (global) |
Allowable individual loads at the nozzle end without influence of other loads, including pressure1
Allowable forces, kN | Allowable moments, kN·m | Allowable pressure, MPa | ||||
Fx | Fy | Fz | Mx | My | Mz | [p] |
92.8395 | 150.3298 | 135.0298 | 59.5217 | 102.8768 | 31.9449 | 1.5082 |
Note:
1. When exceeding any loading component, a reinforcing of nozzle connection is required. Or this loading component must be reduced.
Allowable loads at the nozzle end at the design pressure2
Allowable forces, kN | Allowable moments, kN·m | Design pressure, MPa | ||||
Fx | Fy | Fz | Mx | My | Mz | p |
14.5314 | 23.5298 | 21.1351 | 9.3164 | 16.1024 | 5.0001 | 0.8000 |
Note:
2. When exceeding one or several loading components, a supplementary calculation of strength is required.